Home » Products » Rugged Cisco Series Switches » Rugged Cisco 3010 Series Switch
The ruggedized Cisco 3010 Series Switch is engineered to endure extreme environments while providing superior bandwidth and performance. Enhancing uptime, performance, and safety for military systems and equipment in a variety of environments.
Height | 1.75 in |
---|---|
Width | 17.5 in |
Depth | 14.0 in |
Weight | 12 lbs |
Power | 24/28VDC |
Switch Ports | 16 |
Port Type | SFP |
Operational Temperature Testing | MIL-STD-810F, Method 501.5 Procedures I/II; -15°C to +55°C |
Storage Temperature Testing | MIL-STD-810F, Method 501.5 Procedures I/II; -15°C to +55°C |
Humidity Testing | MIL-STD-810F, Method 507.4; 48 Hour, 95% RH 40-65C (with conformal coat option) |
Altitude Testing | MIL-STD-810F, Method 500.4; 12,500ft operation with 40,000ft transport |
Vibration Testing | MIL-STD-810G, Method 514.6 Procedure I; 4.43 GRMS, 5-20000Hz, 60min/axis |
Shock Testing | MIL-STD-810G, Method 516.6, Procedures I/V; 20g, 11msec - functional shock; 40g, 11msec crash hazard shock |
Other Testing | MIL-STD-461F CE & RE emissions |
Environmental Specifications | Tested to meet military environmental specifications. |
Operational Temperature | MIL-STD-810F, Method 501.5 Procedures I/II; -15°C to +55°C |
Storage Temperature | MIL-STD-810F, Method 501.5 Procedures I/II; -15°C to +55°C |
Humidity | MIL-STD-810F, Method 507.4; 48 Hour, 95% RH 40-65C (with conformal coat option) |
Altitude | MIL-STD-810F, Method 500.4; 12,500ft operation with 40,000ft transport |
Vibration | MIL-STD-810G, Method 514.6 Procedure I; 4.43 GRMS, 5-20000Hz, 60min/axis |
Shock | MIL-STD-810G, Method 516.6, Procedures I/V; 20g, 11msec - functional shock; 40g, 11msec crash hazard shock |
Other | MIL-STD-461F CE & RE emissions (with 461 filter option) |
Environmental Specifications | Tested to meet military environmental specifications. |
---|---|
Operational Temperature | MIL-STD-810F, Method 501.5 Procedures I/II; -15°C to +55°C |
Storage Temperature | MIL-STD-810F, Method 501.5 Procedures I/II; -15°C to +55°C |
Humidity | MIL-STD-810F, Method 507.4; 48 Hour, 95% RH 40-65C (with conformal coat option) |
Altitude | MIL-STD-810F, Method 500.4; 12,500ft operation with 40,000ft transport |
Vibration | MIL-STD-810G, Method 514.6 Procedure I; 4.43 GRMS, 5-20000Hz, 60min/axis |
Shock | MIL-STD-810G, Method 516.6, Procedures I/V; 20g, 11msec - functional shock; 40g, 11msec crash hazard shock |
Other | MIL-STD-461F CE & RE emissions (with 461 filter option) |
Fill out the form for pricing and information