Rugged PCC - Core Systems

Rugged PCC

Rugged Mission Computers

The rugged PCC01 Mission Computer from Core Systems is a rugged custom-built sealed fanless tactical computer build for the military.

  • Extended temperature design with a range of -40C to +85C.
  • Tested for MIL-S-901D Shock, MIL-STD-167-1 Vibration, MIL-STD-810G Shock & Vibration, MIL-STD-810F Humidity, and MIL-STD-461E/F EMC.
  • Includes a 500GB solid-state drive which is installed in a removable carrier.
  • Application-Specific
  • Military-Grade Design

  • Extended temperature design with a range of -40C to +85C.
  • Tested for MIL-S-901D Shock, MIL-STD-167-1 Vibration, MIL-STD-810G Shock & Vibration, MIL-STD-810F Humidity, and MIL-STD-461E/F EMC.
  • Includes a 500GB solid-state drive which is installed in a removable carrier.
  • Application-Specific
  • Military-Grade Design

Height 6.50 in
Width 11.00 in
Depth 11.00 in
Weight 6.50 lbs
Power 28VDC
RAM 8GB
Processor Latest Intel CPU
Storage One (1) 2.5” 500GB SSD drive
Cores 4-12x
Environmental Specifications Tested to meet military environmental specifications.
Operational Temperature MIL-STD-810F, Method 501.5 Procedures I/II; -15°C to +55°C
Storage Temperature MIL-STD-810F, Method 501.5 Procedures I/II; -15°C to +55°C
Humidity MIL-STD-810F, Method 507.4; 48 Hour, 95% RH 40-65C (with conformal coat option)
Altitude MIL-STD-810F, Method 500.4; 12,500ft operation with 40,000ft transport
Vibration MIL-STD-810G, Method 514.6 Procedure I; 4.43 GRMS, 5-20000Hz, 60min/axis
Shock MIL-STD-810G, Method 516.6, Procedures I/V; 20g, 11msec - functional shock; 40g, 11msec crash hazard shock
Other MIL-STD-461F CE & RE emissions (with 461 filter option)
Environmental Specifications Tested to meet military environmental specifications.
Operational Temperature MIL-STD-810F, Method 501.5 Procedures I/II; -15°C to +55°C
Storage Temperature MIL-STD-810F, Method 501.5 Procedures I/II; -15°C to +55°C
Humidity MIL-STD-810F, Method 507.4; 48 Hour, 95% RH 40-65C (with conformal coat option)
Altitude MIL-STD-810F, Method 500.4; 12,500ft operation with 40,000ft transport
Vibration MIL-STD-810G, Method 514.6 Procedure I; 4.43 GRMS, 5-20000Hz, 60min/axis
Shock MIL-STD-810G, Method 516.6, Procedures I/V; 20g, 11msec - functional shock; 40g, 11msec crash hazard shock
Other MIL-STD-461F CE & RE emissions (with 461 filter option)

Related Product Designs

All products can be customized to your specs and requirements.

Request A Quote Today

Fill out the form for pricing and information